Enabled
Usage Guide:
To enable System PoE Admin Mode.
Example:
To enable System PoE Admin Mode.
Switch# configure terminal
Switch (config)# poe admin-mode enable
4.2.137 poe management mode
Command:
poe management mode { class-consumption | class-reserved-power |
allocation-consumption | allocation-reserved-power | lldp-consumption |
lldp-reserved-power }
poe Power Over Ethernet
management Use management mode to configure PoE power management method.
mode mode
allocation-consumption Max. port power determined by allocated, and power is managed according to power
consumption.
allocation-reserved-power Max. port power determined by alocated, and is managed according to reserved power.
class-consumption Max. port power determined by class, and power is managed according to power consumption.
class-reserved-power Max. port power determined by class, and power managed according to reserved power.
lldp-consumption Max. port power determined by LLDP Media protocol, and power is managed according to
consumption.
lldp-reserved-power Max. port power determined by LLDP Media protocol, and power is managed according to
reserved power.
Default:
Allocation-consumption
Usage Guide:
To configure PoE Management Mode.
Example:
To configure PoE Management Mode as LLDP-consumption mode.